XBGCS AC low-voltage complete switching equipment Custom

Home / Products / Low Voltage Complete Electrical Equipment / XBGCS AC low-voltage complete switching equipment
Wenzhou Xubian Electric Co., Ltd.
  • XBGCS AC low-voltage complete switching equipment
  • XBGCS AC low-voltage complete switching equipment
100012 Model Designation
XB Enterprise code
G Enclosed switchgear cabinet
C Draw-out type
S System
□ Main circuit scheme number

1. Ambient air temperature shall not exceed +40°C and shall not be lower than -5°C, and the average temperature within 24 hours shall not exceed +35°C. When exceeded, the equipment shall be derated for operation according to actual conditions;
2. For indoor use, the altitude of the installation site shall not exceed 2000 m;
3. The relative humidity of the ambient air shall not exceed 50% at a maximum temperature of +40°C. A higher relative humidity is permitted at lower temperatures, for example 90% at +20°C, but the effect of condensation that may occasionally occur due to temperature changes shall be taken into account;
4. During installation, the inclination from the vertical shall not exceed 5°, and the whole row of cabinets shall be relatively level (in compliance with GBJ232-82 standard);
5. The device shall be installed in places free from severe vibration and shock, and where electrical components are not subject to corrosion.

No. Item Parameter
1 Rated voltage of main circuit (V) AC 400/660
2 Rated voltage of auxiliary circuit AC 220, 380 (400); DC 110, 220
3 Rated frequency (Hz) 50 (60)
4 Rated insulation voltage (V) 660
5 Rated current (A) Horizontal busbar ≤ 5000
5 Rated current (A) Vertical busbar (MCC) 1000
6 Rated short-time withstand current of busbar (kA/1s) 50, 80
7 Rated peak withstand current of busbar (kA/0.1s) 105, 176
8 Power frequency test voltage (V/1min) Main circuit 2500
8 Auxiliary circuit 2000
9 Busbar Three-phase four-wire system A.B.C.PEN
9 Three-phase five-wire system A.B.C.PE.N
10 Degree of protection IP30, IP40

I. Main Circuit Schemes
The main circuit schemes of the XBGCS cabinet total 32 groups and 118 specifications, not including schemes and specifications derived from changes in the control and protection of auxiliary circuits. They include the needs of power generation, power supply, and other power users, with a rated operating current of up to 5000A, suitable for selection with distribution transformers of 2500kVA and below. In addition, to meet the needs of power supply systems with high power factor requirements, capacitor compensation cabinets are designed, and reactor cabinets can be selected based on comprehensive investment needs.
II. Auxiliary Circuit Schemes
The XBGCS auxiliary circuit diagram collection contains a total of 120 auxiliary circuit schemes, divided into two volumes. The first volume, "AC Operation Part", has 63 schemes in total, and the second volume, "DC Operation Part", has 57 schemes in total. The auxiliary circuit schemes of the DC operation part are mainly used for the low-voltage auxiliary (station) power systems of power plants and substations. They are suitable for the low-voltage auxiliary power systems of units of 200MW and below and 300MW and above, and are general control methods for working (standby) power incoming lines, power feeder lines, and motor feeder lines.
The auxiliary schemes of the AC operation part are mainly used for the low-voltage power distribution of substations in industrial and mining enterprises and high-rise buildings. There are 6 combination schemes suitable for dual-power-supply operation control, with operating electrical interlocking and automatic/self-recovery control circuits, which can be directly adopted in engineering design.
The DC-controlled control power supply is DC 220V or 110V, and the AC control power supply is AC 380V or 220V, composed of draw-out unit assembly cabinets. The 220V control power supply is a common control power supply supplied by a dedicated control transformer in the cabinet itself. The common control power transformer uses an ungrounded control transformer, and a 24V power supply is reserved for use when weak-current signal lamps are needed.
For the installation location of the electricity meters, the method of introducing voltage signals, and their installation and use requirements, please refer to the "Compilation Notes" of the auxiliary circuit diagrams.
III. Main Busbars
1. To improve the thermal stability of the busbars and improve the temperature rise of the contact surfaces, all equipment uses TMY-T2 series hard copper busbars, with the copper busbars fully tin-plated, and fully silver-plated copper busbars can also be selected.
2. The horizontal busbars and vertical busbars are installed separately in isolated compartments inside the cabinet.
3. The neutral grounding busbar uses a hard copper busbar. It is a continuous horizontal protective earth neutral (PEN) or grounding + neutral (PE+N).
IV. Selection of Electrical Components
1. GCS cabinets mainly use electrical components with high technical standards and stable performance indicators, and electrical components that have been mass-produced domestically with imported technology.
2. Main switch
For incoming and feeder switches of 630A and above, the DW45 series is mainly selected; the DW48 series, AE series, 3WE or ME series can also be selected; if considered necessary, imported M series or F series can also be selected.
3. For feeder and motor control switches below 630A, molded case series such as the TG series, CM1 series, NM series, CDM series, and TG30 series are mainly selected.
4. To improve the dynamic stability of the main circuit, a combined busbar clamp and insulating support dedicated to the GCS series have been designed, molded from high-strength, flame-retardant synthetic thermoplastic materials, with high insulation strength, good self-extinguishing performance, and a unique structure.
5. To reduce the temperature rise of the partition plates, plug-in connectors, and cable lugs between functional units, a dedicated adapter for GCS cabinets has been designed, with large adapter capacity and reduced temperature rise.
6. When the design department selects new electrical components with better performance and more advanced technology according to user needs, because the GCS series cabinets have good versatility, it will not cause difficulties in manufacturing and installation due to frequent updates of electrical components.

Dimensions (mm)
Cabinet Height (H) 2200
Cabinet Width (D) 400 600 800 1000
Cabinet Depth (W) 800 1000 800 1000 600 800 1000 600 800 1000
No. Item Sub-item
1 Verticality 3.3
2 Levelness Top of two adjacent cabinets 2
2 Top of cabinets in a row 5
3 Unevenness Edge of two adjacent cabinets 1
3 Edge of cabinets in a row 5
4 Gap between cabinets 2
100003 Side view: H=2200, D
Front/installation view: ≥800, W, ≥1800; Trench / Cable trench outer dimensions to be determined by the user (note near the bottom of the drawing); "Embedded steel" label
Bottom view: 4-14×30, W-44, W, D-150, D
About Us

XUBIAN ELECTRIC POWER YOU CAN TRUST

Wenzhou Xubian Electric Co., Ltd.
  • 10+

    Years Experience

Wenzhou Xubian Electric Co., Ltd. is a technology-driven China XBGCS AC low-voltage complete switching equipment Supplier and Custom XBGCS AC low-voltage complete switching equipment Factory, specializing in the production, sales and after-sales maintenance of high- and low-voltage complete switchgear systems.

We have a dynamic and innovative team for R&D, design, management and marketing, backed by solid R&D and production competence.

Following our quality policy: “Survival through Quality, Development through Innovation, Continuous Improvement, Customer Satisfaction”, we enforce strict control over all production stages to ensure 100% qualified finished goods. Our workshop is well‑equipped with full‑range processing facilities, testing apparatus and advanced inspection solutions.

View More
Wenzhou Xubian Electric Co., Ltd.

Company Philosophy

Quality Centered, Quality First, Win-Win Cooperation

Company Mission

To become a trusted global manufacturing partner for power transmission and distribution equipment.
  • Factory equipment
  • Factory equipment
  • Factory equipment
  • Factory equipment
  • Factory equipment
  • Factory equipment
  • Factory equipment
  • Factory equipment
  • Warehouse
  • Warehouse
News Center

Keep Up To Date With Our Latest News.

View More

Certificate Of Honor

  • 1
  • 2