Our outdoor high-voltage vacuum/SF6 circuit breaker series is widely used in urban distribution overhead lines, industrial/mining power supply, and rural grid renovation projects, covering intelligent-type, primary-secondary integrated vacuum circuit breakers, and ceramic column SF6 circuit breakers, reliably switching load, overload, and short-circuit currents.
The equipment offers excellent anti-pollution flashover and weather resistance, adapting to harsh outdoor conditions such as high heat, extreme cold, and salt fog; some models support remote control, fault recording, and GSM SMS alarm functions. Customized solutions are available based on the local grid's voltage class, short-circuit capacity, and intelligence requirements, together with installation, commissioning, and remote technical support.
Wenzhou Xubian Electric Co., Ltd. is a technology-driven China Outdoor Vacuum Circuit Breaker Manufacturer and Custom 12kV Pole Mounted Circuit Breaker Supplier, specializing in the production, sales and after-sales maintenance of high- and low-voltage complete switchgear systems.
We have a dynamic and innovative team for R&D, design, management and marketing, backed by solid R&D and production competence.
Following our quality policy: “Survival through Quality, Development through Innovation, Continuous Improvement, Customer Satisfaction”, we enforce strict control over all production stages to ensure 100% qualified finished goods. Our workshop is well‑equipped with full‑range processing facilities, testing apparatus and advanced inspection solutions.
Wenzhou Xubian Electric Co., Ltd. is a China Outdoor Vacuum Circuit Breaker Manufacturer producing outdoor high-voltage vacuum and SF6 circuit breakers for 12 kV, 40.5 kV and 72.5 kV distribution systems. The range covers pole-mounted vacuum breakers, intelligent and primary-secondary integrated models, and ceramic-column SF6 breakers for overhead lines, industrial and mining supply, and rural grid renovation.
We assemble each unit around a vacuum interrupter or SF6 chamber, current transformers, spring operating mechanism and steel enclosure. Voltage class, rated current, short-circuit capacity, control voltage and communication method are fixed at configuration stage, then verified in factory tests before export packing.
The Outdoor High-Voltage Vacuum/SF6 Circuit Breaker Series is organised around three application groups. Each group uses the same engineering approach: interruption medium matched to voltage, mechanism matched to operating duty, and controls matched to the automation interface at site.
ZW32-12, ZW32-12F intelligent type, ZW32M(T)-12 primary-secondary integration, ZW20-12F and ZW8-12(G) for overhead distribution, frequent switching and remote monitoring.
ZW32-40.5 with integrated solid-sealed pole and ZW7-40.5 for 35 kV substations, industrial lines and high-load distribution points.
LW36-72.5 ceramic-column SF6 circuit breaker for high-voltage AC networks where SF6 interruption and porcelain column construction suit the line layout.
| Voltage class | Models in our range | Interruption medium | Typical installation | Application fit |
|---|---|---|---|---|
| 12 kV | ZW32-12, ZW32-12F, ZW32M(T)-12, ZW20-12F, ZW8-12(G) | Vacuum, solid-sealed pole | Pole or structure mounted | Urban overhead lines, industrial and mining supply, rural grid renovation |
| 40.5 kV | ZW7-40.5, ZW32-40.5 | Vacuum | Column or structure mounted | 35 kV substations, industrial lines and medium-voltage overhead networks |
| 72.5 kV | LW36-72.5 | SF6 | Ceramic column | High-voltage AC transmission and distribution points |
Rated values are confirmed against the project working point rather than selected from a single catalogue column. The table below shows the standard parameters of three frequently specified models; other models in the range are configured to the same technical logic.
| Model | Rated voltage | Rated current | Rated short-circuit breaking current | Mechanical life |
|---|---|---|---|---|
| ZW32-12F intelligent outdoor vacuum circuit breaker | 12 kV | 630 / 1250 A | 20 / 25 kA | 10,000 operations |
| ZW7-40.5 outdoor vacuum circuit breaker | 40.5 kV | 1250 / 1600 / 2000 A | 20 / 25 / 31.5 kA | 10,000 operations |
| ZW32-40.5 outdoor vacuum circuit breaker | 40.5 kV | 630 / 1250 A | 25 / 31.5 kA | 10,000 operations |
Outdoor breakers must hold insulation margins through pollution, temperature swing, wind load and mechanical shock. Our vacuum models use a longitudinal magnetic field contact structure that keeps the arc diffuse, supports low arc voltage and restores dielectric strength quickly at current zero. The ZW32-40.5 uses an integrated solid-sealed pole; the LW36-72.5 uses an SF6 chamber in ceramic column construction.
Each breaker is built around a spring operating mechanism with motor and manual energy storage, closing and opening solenoids, and automatic recharging in the closed state for reclosing duty. Control voltages are selected from DC 220 V, AC 220 V or AC/DC 220 V according to the station auxiliary supply.
Intelligent models accept current transformer ratios such as 200/5, 400/5 and 600/5, an overcurrent release rated at 5 A, and remote control through cable, optical fibre, GPRS/CDMA or GSM channels. The ZW32M(T)-12 adds primary-secondary integration with directional judgment for fault isolation on branched overhead lines. Breakers are also prepared for integration with our high-voltage complete switchgear and box-type substations where the project uses a packaged distribution scope.
Quality control follows the production route rather than a final visual check. Incoming materials and purchased components are inspected on arrival; patrol checks cover assembly, wiring and mechanism build; semi-finished units pass insulation resistance, voltage withstand and DC resistance tests before moving forward. Finished breakers receive voltage withstand, temperature-rise and function verification, and are released only after full factory qualification.
A suitable proposal depends on the line interface and operating duty, not only the breaker model number. We use the following project inputs to fix the configuration, test scope and quotation.
Standard models typically move in 7 to 15 working days; OEM and ODM schedules are set after drawings, component configuration and branding are confirmed. Goods are packed to export standards with loading information, test reports and manuals. Installation guidance and online technical support cover mechanism adjustment, control wiring, commissioning checks and troubleshooting.
Equipment carries a 12-month repair, replacement and return warranty, with spare parts available after the warranty period. For project equipment we support on-site unpacking, installation and commissioning coordination, and we keep technical documents available for long-term maintenance planning.
Our range includes ZW32-12, ZW32-12F intelligent type, ZW32M(T)-12 primary-secondary integration, ZW20-12F, ZW8-12(G), ZW7-40.5, ZW32-40.5 and the LW36-72.5 ceramic-column SF6 breaker. We select the model family by voltage class, short-circuit level, installation method and automation requirement.
Yes. The ZW32-12F and ZW32M(T)-12 support remote control and monitoring, with communication through cable, optical fibre, GPRS/CDMA or GSM. Primary-secondary integrated configurations add directional judgment for fault handling on branched overhead lines.
Our 12 kV intelligent model is rated 630 to 1250 A with 20 to 25 kA short-circuit breaking current. The ZW7-40.5 covers 1250 to 2000 A and 20 to 31.5 kA, while the ZW32-40.5 covers 630 to 1250 A and 25 to 31.5 kA. Final ratings are confirmed against the project working point.
Models are designed and tested against GB1984-2003, GB/T11022-1999 and IEC 62271-100, with model-specific references including DL/T 402 and IEC 60056. Routine tests include insulation resistance, power-frequency voltage withstand, main-circuit resistance, mechanical operation and function checks, with a test report issued for each unit.
Send the system voltage, frequency, rated current, short-circuit capacity, control voltage, CT ratio, communication requirement, pollution class, temperature range, altitude and installation method. If the breaker will sit inside switchgear or a box-type substation, include the interface drawing so we can confirm the mounting and wiring scope.
We support OEM and ODM work covering electrical parameters, structural drawings, private-label branding and packing. Export documents, loading information, manuals and test reports are prepared with the shipment, and our after-sales team provides online installation guidance and troubleshooting.