High Voltage Switchgear Custom

Home / Products / High-Voltage Complete Switchgear
Wenzhou Xubian Electric Co., Ltd.
About Us

XUBIAN ELECTRIC POWER YOU CAN TRUST

Wenzhou Xubian Electric Co., Ltd.
  • 10+

    Years Experience

Wenzhou Xubian Electric Co., Ltd. is a technology-driven China High Voltage Switchgear Manufacturer and Custom Switchgear for Mining Substation Supplier, specializing in the production, sales and after-sales maintenance of high- and low-voltage complete switchgear systems.

We have a dynamic and innovative team for R&D, design, management and marketing, backed by solid R&D and production competence.

Following our quality policy: “Survival through Quality, Development through Innovation, Continuous Improvement, Customer Satisfaction”, we enforce strict control over all production stages to ensure 100% qualified finished goods. Our workshop is well‑equipped with full‑range processing facilities, testing apparatus and advanced inspection solutions.

View More
Wenzhou Xubian Electric Co., Ltd.

Company Philosophy

Quality Centered, Quality First, Win-Win Cooperation

Company Mission

To become a trusted global manufacturing partner for power transmission and distribution equipment.
  • Factory equipment
  • Factory equipment
  • Factory equipment
  • Factory equipment
  • Factory equipment
  • Factory equipment
  • Factory equipment
  • Factory equipment
  • Warehouse
  • Warehouse
News Center

Keep Up To Date With Our Latest News.

View More

Certificate Of Honor

  • 1
  • 2
High-Voltage Complete Switchgear Industry knowledge

Wenzhou Xubian Electric Co., Ltd. is a High Voltage Switchgear Manufacturer based in Liushi Town, Yueqing, Zhejiang, producing complete AC metal-enclosed switchgear for 12 kV, 24 kV and 40.5 kV distribution systems. Our cabinets serve substations, power plants, industrial plants and mining substations, and ship together with the vacuum circuit breakers, earthing switches, reactive power compensation devices and DC control screens that complete a distribution room.

Built, Assembled and Tested Under One Roof

Sheet-metal processing, busbar fabrication, primary and secondary wiring, assembly and factory testing run inside our own workshop in Yueqing, so the cabinet that leaves the line is the one our inspectors tested. Production follows the GB3906 and GB/T11022 metal-enclosed switchgear standards used on our domestic projects, with IEC 62271 and DL404 requirements applied where the destination grid or consultant specification calls for them.

Our engineering team works upward from the single-line diagram: normal and fault current, system earthing, cable or overhead entry, protection and control philosophy, and site ambient conditions together determine the final cabinet arrangement and component list.

  • Armoured withdrawable and fixed metal-enclosed constructions in one product family.
  • Vacuum circuit breakers, isolating switches, earthing switches and surge arresters integrated at assembly stage.
  • Protection relays, metering, intelligent monitoring and remote signalling wired to the customer's control scheme.
  • OEM and ODM builds to local grid standards, voltage class and control mode.

Our High-Voltage Complete Switchgear Range

Five switchgear families cover the distribution duty from 12 kV industrial boards through to 40.5 kV substation incomers, with ratings selected per project rather than fixed at catalogue level.

Model Rated voltage Rated current Short-time withstand (4 s) Construction and fit
KYN28-12(Z) 3.6 / 7.2 / 12 kV 630–3150 A 16–50 kA Metal-clad withdrawable, four compartments, IP4X, front access and back-to-wall installation
KYN28A-24 24 kV Per project scheme Per project scheme Armoured withdrawable metal-enclosed, 24 kV distribution and plant substations
KYN61-40.5(Z) 40.5 kV 1250 / 1600 / 2000 A 20 / 25 / 31.5 kA Armoured withdrawable, IP3X, 2650 mm cabinet height, frequent-operation duty
XBXGN-40.5 40.5 kV 1600 A 25 kA Fixed metal-enclosed, single busbar or single busbar with bypass, IP2X
SRM-12 12 kV Set by cable and ring scheme Set by cable and ring scheme Fully sealed, fully insulated inflatable ring network switchgear for compact and outdoor points

Reactive power and control-power equipment is supplied in the same category so a distribution room can be completed from one drawing set and one delivery.

TBBZ automatic compensation

Capacitor bank switching on the high-voltage busbar with automatic control, improving power factor and reducing line losses.

XBBBR-12 compensation switching

Intelligent reactive power compensation switching equipment for 12 kV distribution rooms and plant networks.

XBGZDW DC screen

High-frequency DC control supply for protection relays, breaker operating coils and remote monitoring circuits.

Application Fit Across Substations, Plants and Mining Loads

The withdrawable metal-clad series suits substations and plant main distribution boards where circuits must be isolated and returned to service quickly, and where a spare truck keeps downtime short. Fixed metal-enclosed cabinets fit single-busbar substations and bypass arrangements where the circuit breaker is inspected in place.

Mining substations, crusher and mill drives, ventilation fans and hoisting loads see high starting current, dust and wide temperature swings; those projects are configured with the higher short-circuit ratings in the range, mechanical interlocks, anti-condensation heating and enclosure grades agreed at order stage. Where the distribution room is cramped or located outdoors, the sealed inflatable ring network units and our 12kV medium voltage complete switchgear equipment reduce footprint and maintenance access requirements.

For prefabricated projects we combine high-voltage switchgear, transformer and low-voltage section inside a box-type substation, allowing all connections and routine testing to be completed before shipment.

Configuration Choices That Shape the Lineup

Breaker, busbar and earthing arrangement

We match the busbar system to the network — single busbar, single busbar with bypass, or sectionalised — and select vacuum circuit breaker, load switch or isolating switch per circuit function. Earthing switches, shutters and mechanical interlocks are built into the compartment layout so cable earthing and truck racking follow a fixed sequence.

Insulation, enclosure and protection class

Air-insulated metal-clad cabinets are standard for indoor rooms; sealed inflatable and solid-insulated designs are used where humidity, pollution or space rules out open air insulation. Enclosure ratings across the range move from IP2X on fixed cabinets to IP4X on the withdrawable 12 kV series, with the appropriate class confirmed against the room environment.

Control, protection and automation integration

Each cabinet is wired for manual, electrical or intelligent remote operation, with current and voltage transformers, surge arresters, protection relays and monitoring devices selected to the customer's scheme. Secondary wiring is brought to terminal blocks and a secondary plug on the withdrawable truck, ready for connection to plant SCADA, and the DC screen provides the control supply for trip and close circuits.

Compartments, Materials and Mechanical Detail

The withdrawable 12 kV cabinet is divided into busbar, circuit breaker truck, cable and relay compartments, with pressure relief, internal partitions and insulating sleeves around the busbar and contact boxes. Cold-rolled sheet steel forms the enclosure, and busbars, current transformers, earthing switches and cable terminations are arranged for front-side access.

  • Removable truck with secondary plug for quick circuit substitution.
  • Shutters and horizontal partitions separating live parts from the operator aisle.
  • Anti-condensation heating in humid or coastal installations.
  • Foundation frames prepared for bolted or welded fixing to embedded channel steel.

Factory Testing, Acceptance and Documentation

Incoming sheet steel, busbar and purchased components are inspected on arrival, and QC patrols cover assembly and wiring before any cabinet reaches the test bay. Semi-finished units pass insulation resistance, power-frequency voltage withstand and DC resistance checks; finished cabinets then go through voltage withstand, temperature-rise and functional verification before a test report is issued.

For non-standard or OEM builds we manufacture and test a prototype for insulation and voltage-withstand approval before mass production starts. Shipments carry the approved drawings, test reports and operation manuals, and we confirm the certification route for the destination market before production so documentation matches the project file.

Site Conditions, Installation and Utilities

Standard service conditions across the range are an ambient maximum of +40 °C, altitude up to 1000 m, seismic intensity up to 8 degrees and daily average relative humidity up to 95%, with lower temperature limits of −15 °C or −25 °C depending on the model. Conditions outside these values are agreed with our engineers at the ordering stage and reflected in the design.

  • Foundation frame flatness within 1 mm/m, with embedded channel steel protruding no more than 3 mm above floor level.
  • Single-row operating aisle of at least 3000 mm; 4000 mm for face-to-face double rows.
  • Rear clearance of at least 1500 mm and electrical room height of at least 4500 mm for the 40.5 kV withdrawable units, whose cabinet weight is approximately 1800 kg.
  • Cable basement or overhead entry trenches prepared before cabinets are positioned and bolted down.

Maintenance, Spare Parts and Serviceability

Truck-mounted breakers can be withdrawn for inspection without exposing the busbar, and vacuum interrupters in the range are maintenance-free in normal service. We supply consumable and wearing parts after the warranty period, and online technical support answers troubleshooting questions during commissioning and operation. Installation guidance and operator training material are provided with each shipment.

Information We Use to Configure Your Solution

  • Single-line diagram, system voltage, busbar arrangement and circuit count.
  • System short-circuit level and required short-time withstand current and duration.
  • Continuous current per incomer and outgoing feeder, plus busbar rating.
  • Cable or overhead entry, cable sizes and gland plate arrangement.
  • Protection and metering scheme, CT/VT ratios, relay types and communication protocol.
  • Control mode — manual, electrical or remote SCADA — and DC screen capacity and voltage.
  • Site ambient temperature, humidity, altitude, seismic intensity and corrosion or dust exposure.
  • Required enclosure protection class, room dimensions, aisle widths and installation code.
  • Local grid standard, market certification route and documentation language.
  • Branding, drawing approval route, packing and shipping terms.

Frequently Asked Questions

Which voltage classes and ratings do you build?

Our complete switchgear covers 3.6, 7.2 and 12 kV up to 3150 A and 50 kA, 24 kV armoured withdrawable units, and 40.5 kV cabinets at 1250–2000 A with 20–31.5 kA short-time withstand current. Final ratings are fixed per project scheme.

Can the lineup be built to our local grid standard?

Yes. Our OEM and ODM service covers cabinet structure, component selection, voltage class, control mode, branding and documentation based on the grid standard and installation code of your market.

What does a delivery include?

Main cabinets with breakers, current transformers, earthing switches and surge arresters, secondary wiring to terminal blocks, approved drawings, factory test reports, operation manuals and export packing, with loading information supplied for shipping.

How is control power and automation handled?

We integrate protection relays and monitoring devices, wire remote signalling to the customer's protocol, and supply XBGZDW DC screens where the project needs a dedicated control supply for trip and close circuits.

What are typical lead times?

Standard models are scheduled at 7–15 working days. OEM and ODM cabinets are scheduled after drawings and specifications are confirmed, and non-standard designs pass prototype insulation and voltage-withstand testing before production.

What support follows shipment?

Each cabinet carries a 12-month repair, replacement and return warranty, spare parts remain available after that period, and online technical support answers installation and troubleshooting questions during commissioning.

Related Products and Categories

Our portfolio also includes KYN61-40.5(Z) Armoured removable AC metal enclosed switchgear for applications with different operating ranges, interfaces or integration requirements.