Quick answer

Choose an indoor vacuum circuit breaker when the breaker sits inside metal-enclosed switchgear, and choose an outdoor vacuum circuit breaker when it hangs on an overhead line or stands in a yard. Within the indoor range, take the handcart type for withdrawable cabinets such as KYN28A-12 and the fixed type for XGN cabinets and ring main units. Our indoor vacuum circuit breaker series covers 12 kV to 40.5 kV, and the sister outdoor range is built by a China Outdoor Vacuum Circuit Breaker Manufacturer with the same quality system.

20,000Mechanical operations, 12 kV ZN63 and 24 kV VS1
630 to 4000 ARated current, 12 kV family
20 to 40 kAShort-circuit breaking current
7 to 15 daysStandard model scheduling

How to Choose an Indoor Vacuum Circuit Breaker

A breaker is only correct when it fits the cabinet, the network and the duty cycle at the same time. Work through four decisions in order, and most selection mistakes disappear before the drawing stage.

01Voltage classPick 12 kV, 24 kV or 40.5 kV to match the busbar. Models are ZN63(VS1)-12, VS1-24 and ZN85-40.5.
02Current and fault levelAt 12 kV, rated current runs from 630 A to 4000 A with 20/25, 31.5 and 40 kA breaking capacity.
03Mounting styleFixed, handcart, side-mounted or three-position, chosen from the cabinet drawing.
04Control supplyAC or DC 110 V and 220 V coils for closing and opening, matched to the station supply.

Check the site limits at the same time. Standard conditions are an ambient temperature between minus 10 and plus 40 degrees Celsius, altitude up to 1000 m, daily average humidity up to 95 percent and seismic intensity up to Grade 8. Above 1000 m the insulation level is raised and the rating is agreed in writing.

Selection tip: Send the cabinet drawing with phase spacing and depth. The ZN63 family is available for 275 mm phase spacing as well as the standard layout, and a mismatch found after production is expensive to correct.

Fixed or Handcart Vacuum Circuit Breaker: Which Is Better

Both types share the same electrical design. The operating mechanism is integrated with the breaker body, so the unit can be bolted in as a fixed breaker or fitted with a dedicated propulsion mechanism to become a handcart. The better choice is the one that matches the cabinet and the maintenance routine.

Handcart type ZN63(HR1)-12 and ZN63(VS1)-12 handcart for KYN28A-12 (GZS and GZS1) Rack between service and test positions without opening the busbar Needs the correct engagement dimension of 15 to 25 mm on assembly
Fixed type ZN63(VS1)-12 fixed for XGN cabinets and ring main units Fewer moving parts and simple cable termination Circuit must be isolated upstream before service work
Parameter ZN63(VS1)-12 and ZN63(HR1)-12 VS1-24 ZN85-40.5
Rated voltage 12 kV 24 kV 40.5 kV
Breaking current 20/25, 31.5, 40 kA 20/25, 31.5, 40 kA 25, 31.5 kA
Impulse withstand 75 kV to earth 125 kV to earth 185 kV
Mechanical life 20,000 operations 20,000 operations 10,000 operations
Operating sequence O-0.3 s-CO-180 s-CO O-0.3 s-CO-180 s-CO O-0.3 s-CO-180 s-CO

Vacuum Circuit Breaker Product Series

Browse our indoor vacuum circuit breakers together with selected outdoor and cabinet-side breakers. Swipe or use the arrows to move between models, and open any card for full ratings and dimensional drawings.

Indoor or Outdoor Vacuum Circuit Breaker: Which Is Better

The interrupter technology is the same, but the housing, insulation and controls are not. An indoor breaker relies on the cabinet for protection from weather. An outdoor breaker carries its own sealed enclosure, creepage distance and weather resistance, so it can be mounted on a pole or structure.

For overhead networks, a China 12kV Pole Mounted Circuit Breaker Manufacturer offers ZW32-12, ZW32-12F intelligent type, ZW32M(T)-12 primary-secondary integration, ZW20-12F and ZW8-12(G). ZW32-12 is described as small, light, anti-condensation and maintenance-free, suited to substations, industrial and mining distribution and rural grids that operate frequently.

Factor Indoor vacuum circuit breaker Outdoor vacuum circuit breaker
Installation Inside KYN28 or XGN cabinets, ring main units, box-type substations Pole, column or structure mounted on overhead lines
Voltage classes 12 kV, 24 kV, 40.5 kV 12 kV, 40.5 kV and 72.5 kV SF6
Environment Clean indoor room, minus 10 to plus 40 degrees Celsius Pollution class III or IV, down to minus 40 degrees Celsius in high-cold areas
Typical current 630 to 4000 A at 12 kV 630 / 1250 A at 12 kV intelligent type
Automation Through the cabinet relay or RTU Built-in remote control via cable, optical fibre, GPRS/CDMA or GSM
Do not mix the two: An indoor breaker has no creepage or enclosure margin for rain, salt fog or wind. Outdoor service needs an outdoor model, with wind pressure up to 700 Pa and the correct pollution class confirmed at order.

Which Indoor Vacuum Circuit Breaker Suits Frequent Switching

Vacuum interruption is the right answer when a circuit switches rated current often or clears fault current repeatedly, because the arc is extinguished in a sealed chamber. The ZN63 family is rated for 20,000 mechanical operations and 50 short-circuit breaking operations, while VS1-24 adds an electrical life of 20,000 current breaking operations.

Capacitor and reactive dutyVS1-24 is rated for a single capacitor bank breaking current of 630 A and back-to-back 400 A.
Transformer and motor feedersZN63(VS1)-12 handcart in KYN28A-12 cabinets, with a contact gap of 11 mm and opening time not above 0.05 s.
Compact fixed cabinetsSide-mounted and miniaturized models such as VSC-12 where depth is limited.
35 kV substationsZN85-40.5 with phase spacing of only 300 mm and a breaking time below 80 ms.

How to Source OEM and ODM Vacuum Circuit Breakers from China

Choose a supplier that controls production

A China Outdoor Vacuum Circuit Breaker Supplier should show in-house assembly, wiring and testing rather than relabelled stock. Wenzhou Xubian Electric Co., Ltd. builds its breakers in Liushi Town, Yueqing, Zhejiang. As a China Outdoor Vacuum Circuit Breaker (VCB) Manufacturer it also supplies the indoor range above, so a single order can cover both the line breaker and the cabinet breaker.

OEM, ODM and custom explained

An OEM Outdoor Vacuum Circuit Breaker Supplier builds to your drawings, nameplate and packaging. An ODM Outdoor Vacuum Circuit Breaker Manufacturer starts from a proven design and adjusts voltage, current and control to your grid. A Custom Outdoor Vacuum Circuit Breaker Supplier handles everything outside the catalogue, such as CT ratio, communication channel or pollution class. Each route is fixed by drawing and technical agreement before production.

Factory acceptance in six steps

  1. Incoming inspection. Materials and purchased parts are checked and rejected at source if non-conforming.
  2. Process patrol. QC staff check pole assembly, wiring and mechanism build.
  3. Semi-finished tests. Insulation resistance, voltage withstand and DC resistance.
  4. Finished tests. Voltage withstand, temperature rise and function checks, plus contact gap, overtravel and loop resistance.
  5. Documents. Test report, drawings, manuals and export papers ship with the unit.
  6. After-sales. A 12-month warranty, online support and spare parts beyond the warranty period.
Lead time: Standard models are scheduled at 7 to 15 working days. OEM and ODM breakers follow drawing approval and production planning.

What to send with your enquiry

Include system voltage and frequency, rated current, short-circuit level, mounting method, control voltage, CT ratio, communication needs, pollution class, temperature range, altitude, standards and nameplate language. With these items the first technical reply is quicker and the drawing round is shorter.

Need an indoor or outdoor vacuum circuit breaker Send your cabinet or line drawing to our engineers. See the indoor series, the outdoor series or the contact page.


Interested in cooperation or have questions?