Low Voltage Switchgear Custom

Home / Products / Low Voltage Complete Electrical Equipment
Wenzhou Xubian Electric Co., Ltd.
About Us

XUBIAN ELECTRIC POWER YOU CAN TRUST

Wenzhou Xubian Electric Co., Ltd.
  • 10+

    Years Experience

Wenzhou Xubian Electric Co., Ltd. is a technology-driven China Low Voltage Switchgear Manufacturer and Custom Low Voltage Distribution Cabinet Supplier, specializing in the production, sales and after-sales maintenance of high- and low-voltage complete switchgear systems.

We have a dynamic and innovative team for R&D, design, management and marketing, backed by solid R&D and production competence.

Following our quality policy: “Survival through Quality, Development through Innovation, Continuous Improvement, Customer Satisfaction”, we enforce strict control over all production stages to ensure 100% qualified finished goods. Our workshop is well‑equipped with full‑range processing facilities, testing apparatus and advanced inspection solutions.

View More
Wenzhou Xubian Electric Co., Ltd.

Company Philosophy

Quality Centered, Quality First, Win-Win Cooperation

Company Mission

To become a trusted global manufacturing partner for power transmission and distribution equipment.
  • Factory equipment
  • Factory equipment
  • Factory equipment
  • Factory equipment
  • Factory equipment
  • Factory equipment
  • Factory equipment
  • Factory equipment
  • Warehouse
  • Warehouse
News Center

Keep Up To Date With Our Latest News.

View More

Certificate Of Honor

  • 1
  • 2
Low Voltage Complete Electrical Equipment Industry knowledge

Wenzhou Xubian Electric Co., Ltd. is a China Low Voltage Switchgear Manufacturer supplying complete low voltage distribution and power quality equipment for industrial plants, commercial buildings and residential communities. Our range covers draw-out and fixed switchgear, capacitor compensation cabinets, active filter cabinets, comprehensive distribution cabinets and AC distribution boxes, from the main incoming board to the final lighting circuit. We manufacture to GB/T7251 and configure each assembly around load profile, circuit quantity, installation environment and the control interface required by the project.

Low Voltage Distribution from Main Board to Final Circuit

We organize the range by duty rather than cabinet size alone. Main distribution and motor control assemblies carry the high-current paths; compensation and filtering cabinets correct power quality at the busbar; distribution boxes split final circuits at the point of use. This lets us supply a coordinated package with consistent busbar, protection and labeling conventions across the project.

Product family Models in our range Where it fits Configuration focus
Main LV distribution and motor control XBXL, XBMNS, XBGCK, XBGCS, XBGGD Incoming, bus-tie, feeder and MCC sections in plants, commercial buildings, hotels, airports and infrastructure Rated current, breaker frame sizes, busbar short-time withstand, IP30/IP40, cable entry
Draw-out switchgear XBMNS low voltage draw-out switchgear, XBGCK, XBGGD Processes needing fast module replacement and safe isolation in three-phase five-wire 400/660 V systems Drawer module size, mechanical interlock, PC/MCC mix, 5000 A busbar, 50–80 kA Icw
Reactive compensation XBGGJ low voltage capacitor switchgear, XBJP Main busbar power factor correction and combined distribution/compensation Capacitor stages, switching devices, ventilation, metering and protection
Active harmonic filtering APF active filter cabinet Nonlinear loads such as rectifiers, drives, IT equipment, HVAC and welding systems 50–450 A capacity, 3P3W/3P4W, CT ratio, parallel expansion, Modbus communication
End distribution XBJXF, XBPZ30, XBXM Final circuits in buildings and workshops; lighting, socket and small power distribution Way count, enclosure size, IP rating, door and lock arrangement, circuit labeling
Fire-fighting patrol control XBS-K, XBS-P Fire pump standby integrity in commercial, industrial and residential buildings PLC or intelligent controller, starting method, pump count, alarm interface, patrol cycle

Application Fit by Building Type and Process

Industrial plants use the range for incoming substation distribution, motor control centers, capacitor correction and harmonic filtration where drives and rectifiers distort the supply. Commercial buildings and residential communities use main distribution cabinets, comprehensive compensation cabinets and final distribution boxes for tenant metering, lighting and small power. Airports, docks, hotels and broadcast centers require the same draw-out logic where circuits must be isolated and replaced without shutting down the section.

  • High-current distribution: XBMNS assemblies are rated for three-phase five-wire systems at 400 V or 660 V, with horizontal busbars up to 5000 A and short-time withstand currents of 50, 65 or 80 kA for 1 s.
  • Power quality: APF cabinets target THDi below 5%, while XBGGJ and XBJP cabinets provide staged displacement power factor correction at the main busbar.
  • Space and access: compact distribution boxes and front-access switchgear suit electrical rooms where cable bending radius and maintenance clearance are limited.
  • Fire safety: XBS patrol-inspection equipment keeps standby fire pumps exercised so they do not seize after long idle periods.
  • OEM and ODM: private-label panels, project-specific voltage, enclosure color, nameplate language and drawing sets are handled through our customization process.

Draw-Out and Fixed Construction: Selection Logic

Draw-out construction is the right choice when maintenance access and circuit isolation dominate the operating plan. The XBMNS assembly uses a 25 mm C-section frame, standardized drawer modules and a mechanical interlock that prevents a drawer from being withdrawn under load. PC and MCC sections can be combined on a 200 mm module so incoming, bus-tie and motor feeders share one lineup without losing compartment discipline.

Construction details that affect service life

  • Cabinet bodies are assembled from cold-rolled steel plate after passivation treatment; aluminum-zinc coated steel is available for different user requirements.
  • MCC cabinets use high-strength flame-retardant engineering plastic components for insulation and mechanical support.
  • Incoming, bus-tie, power center, motor control and capacitor cabinets share a 2200 mm height envelope, with width and depth set by circuit and cable-zone requirements.
  • Fixed sections simplify busbar and cable access where withdrawal is not required; draw-out sections reduce downtime where circuits must be changed quickly.

Power Quality: Compensation, Active Filtering and Fire Pump Integrity

The APF active filter cabinet monitors load current through an external CT, extracts harmonic components in its DSP and injects an equal and opposite current through IGBT switching. It suits installations where the harmonic spectrum changes with production or occupancy and passive filters would be difficult to tune. For displacement power factor, XBGGJ capacitor switchgear and XBJP comprehensive cabinets provide staged correction at the main busbar, with switching and ventilation matched to the capacitor bank.

APF reference data

  • Compensation capacity 50, 100, 150, 200 or 300 A, customizable; parallel units expand capacity.
  • 3-phase 3-wire or 3-phase 4-wire; 380 V -40% to +20%; 50 Hz ±10%.
  • Overall efficiency above 97%; THDi below 5%; filtering range 2nd to 50th order.
  • Response time below 300 µs, full response below 10 ms; IGBT equivalent frequency 30 kHz.
  • RS232 and RS485 with Modbus protocol; IP30; 20 kA lightning protection.
  • Ambient 0°C to 40°C; altitude up to 1500 m, with derating above that level.

XBS fire-fighting patrol

XBS-K and XBS-P cabinets use PLC or intelligent controller logic to cycle fire pumps at low speed and low frequency during standby. If a fire signal arrives during patrol, the patrol stops immediately and the pump enters fire-fighting operation according to the configured starting method.

Phase loss, phase failure, output overcurrent and short-circuit conditions raise alarms so the pump remains ready rather than seizing through inactivity.

Technical Envelope and Material Construction

The XBMNS draw-out assembly defines the upper end of our low voltage envelope. Its horizontal busbar is rated up to 5000 A, with a rated insulation voltage of 660/1000 V, a rated frequency of 50 or 60 Hz and a short-time withstand current of 50, 65 or 80 kA for 1 s. Peak withstand current is 105, 140 or 176 kA, and the enclosure is IP30 as standard with IP40 available by special note.

  • Assembly standards: GB7251.1 and IEC60439 for low voltage switchgear and controlgear assemblies; manufacturing follows GB/T7251.
  • Installation conditions: indoor use, ambient air temperature not above +40°C or below -5°C, 24-hour average not above +35°C, altitude not above 2000 m, and a location free from severe vibration and corrosive atmosphere.
  • Humidity: relative humidity up to 50% at +40°C, with higher humidity permitted at lower temperatures; condensation due to temperature changes must be considered.
  • Busbar and cable zones: separate zones for busbars, apparatus and cables support front access and orderly cable termination.
  • Enclosure finish: cold-rolled steel after passivation, with aluminum-zinc coated steel as an option for different corrosion and finish requirements.

Controls, Protection and Automation Integration

Protection and control are configured around the single-line diagram and the plant control philosophy. Incoming and bus-tie frames use the specified breaker series; feeders use molded-case or miniature circuit breakers with the required trip units; metering, CTs, surge protection and status signals are wired to terminal blocks for external SCADA or building management connection. The APF communicates over Modbus RTU on RS485 or RS232, and the XBS patrol cabinet uses PLC or intelligent controller logic with status signals to the fire alarm panel.

  • Control supply: control voltage, trip supply and auxiliary contacts are confirmed against the customer protection scheme.
  • Metering: current, voltage, power, energy and power quality data are selected according to the operating and reporting requirements.
  • Interlocks: breaker, drawer and earthing interlocks are checked functionally before dispatch.
  • Labeling: device labels, circuit schedules and nameplates are produced in the project language and format agreed at technical confirmation.
  • Communication: point lists and protocol details are mapped during drawing review so the cabinet arrives ready for the site network.

Factory Testing, Documentation and Acceptance

Quality control starts with incoming inspection of busbars, breakers, capacitors, filters and sheet-metal parts. In-process checks follow assembly and wiring; semi-finished assemblies are tested for insulation resistance, voltage withstand and DC resistance before they move forward. Finished cabinets receive voltage-withstand, temperature-rise and function tests, and test reports are issued before packing. For non-standard projects, prototypes are manufactured and tested for insulation, temperature rise and voltage withstand for customer approval before mass production.

Typical documentation package

  • Single-line diagram, schematic diagrams, terminal diagrams and general arrangement drawings.
  • Factory test report covering insulation, voltage withstand, temperature rise and functional checks.
  • Operation and maintenance manual, packing list and export documents.
  • Certification support for the target market; relevant products carry CE and CCC certification under an ISO9001 quality system.

Installation, Maintenance and Spare Parts

Draw-out modules allow a circuit to be isolated and replaced without dismantling the busbar; fixed sections are accessed from the front for cable termination and breaker maintenance. APF cabinets include self-diagnosis and protection, and the XBS patrol controller raises alarms on phase, current and short-circuit faults. Spare parts remain available after the warranty period, and our after-sales team provides online troubleshooting in English.

  • Siting: install indoors in a ventilated area free from severe vibration and corrosive atmosphere; confirm front and rear access clearances against the general arrangement drawing.
  • Cable entry: top or bottom entry, gland plate arrangement and bending radius are fixed during drawing review.
  • Warranty: products carry a 12-month warranty for repair, replacement and return; spare parts are available at favorable prices after warranty.
  • Lead time: 7–15 working days for standard models; OEM and ODM products follow the drawing and production schedule confirmed in the proposal.
  • Site support: installation guidance, commissioning support for key-project equipment and 24-hour online after-sales technical support are available.

Information We Use to Configure Your Solution

Our proposal is based on the working point, material and production target. For low voltage assemblies, the working point is the single-line diagram and fault level; the material is the copper busbar, breaker selection, enclosure and cable interface; the production target is the delivery sequence and site installation plan.

  • System data: voltage, frequency, phases, neutral and earthing arrangement, fault level, busbar rating and upstream transformer details.
  • Load data: connected load, demand, power factor, harmonic spectrum, motor starting method and duty cycle.
  • Circuit schedule: incoming, bus-tie, feeder and MCC circuits, spare ways, breaker types, trip units and metering points.
  • Power quality: THDi target, compensation stages, APF capacity, CT ratio and CT location.
  • Environment: indoor or outdoor installation, ambient temperature, humidity, altitude, IP rating and ventilation.
  • Interface: cable entry direction, busway connection, SCADA or BMS protocol, point list and control supply.
  • Documentation and branding: drawing language, nameplate details, enclosure color, manual requirements and test report scope.
  • Delivery: site sequence, shipping marks, packing method and export document requirements.

Frequently Asked Questions

What low voltage equipment does Xubian manufacture?

We manufacture low voltage draw-out and fixed switchgear, capacitor compensation cabinets, APF active filter cabinets, comprehensive distribution and compensation cabinets, AC low voltage distribution cabinets, distribution boxes and fire-fighting patrol-inspection equipment. The range covers main incoming distribution, motor control, power factor correction, harmonic filtering and final circuit distribution.

Can you customize a low voltage switchgear lineup to our single-line diagram?

Yes. We work from the single-line diagram, load schedule and installation conditions to configure busbar ratings, breaker frame sizes, drawer modules, cable entry, metering and labeling. OEM and ODM programs can include private-label panels, project-specific voltage and frequency, enclosure finish and drawing sets.

How do you size APF and capacitor cabinets for a project?

APF capacity is selected from the measured or expected harmonic spectrum, load current and target THDi, using 50–450 A modules with parallel expansion where needed. Capacitor cabinets are staged against the displacement power factor, switching devices, ventilation and permissible harmonic conditions at the busbar.

What testing and documentation accompany the equipment?

Assemblies go through incoming inspection, in-process checks and finished-product factory tests including voltage withstand, temperature rise and function verification. The documentation package includes drawings, factory test reports, operation and maintenance manuals, packing lists and export documents, with certification support for the target market.

What is the lead time and warranty?

Standard models are typically delivered in 7–15 working days. OEM and ODM products follow the drawing and production schedule confirmed in the proposal. Products carry a 12-month warranty for repair, replacement and return, with spare parts available after warranty.

How is installation and after-sales support handled?

We supply installation drawings, manuals and test reports before shipment, then provide online installation guidance and troubleshooting in English. For key-project equipment, on-site unpacking, installation and commissioning support can be arranged, with 24-hour online after-sales technical support.